Urgent need to Drive Tester for Boston Market

Urgent need to Drive Tester for Boston Market

Please send me your Resume at gunjan.laad@amirit.com on an immediate basis or call me on the below nos. Recent TEMS experience is must.
Start Date: ASAP

Thanks & Regards,
Gunjan Laad

AMIRIT TECHNOLOGIES, INC
Office# : (919) 521 5376
Cell # : (919) 593 4039
Email: gunjan.laad@amirit.com

 

2x Implementation Managers

2x Implementation Managers (LOCAL RUSSIAN NATIONALITIES)

I have just received an urgent vacancy from E/// Russia, please help!

I am looking for 2x Implementation Managers to work at Ericsson in Moscow on a 3G rollout.

The Implementation Manager main tasks are to:
" Support Project Manager and project in technical aspects of project implementation issues
" Lead and organize the work within the Implementation function to fulfil the targets
" Coordinates the implementation activities from Site Survey till final Acceptance.
" Ensure that the implementation is carried out in accordance with local requirements, Ericsson instructions and quality requirements.
" Take a leading and supporting role regarding technical issues and solutions within the RAN site engineering and installation services.
" Continuously develop and improve of working methods, processes and procedures within the Project
" Collect and introduce new product and process information, transfer knowledge and experience within the Group

We can only consider Russian Nationals, and the salary is 43,000 roubles net p/month. If someone is good but they want more, please submit them anyway.

Start asap, 6 months plus extension.

Please contact me via mail Marie.chaproniere@NetworkersMSB.com or +442083159819

Immediate Hire Nokia Ultrasite in North and South Carolina.

Immediate Hire Nokia Ultrasite in North and South Carolina.

Please send me your word doc at syed.imran@prithvisolutions.com asap for
the below position.

Position Title: Field Technician (RX-AIT)
Location: North and South Carolina
Duration:4-6+ Months
Rate: $450-500/Site

Description:
Install, test and integrate RX-AIT (Receiver Air Interface Tray)
Verify t1 cable cable path, install RJ45 connectors and loopback, test with
transport.Complete NTP document and submit to NCS along with sweeps and

sweep data form
Method of Procedure
1. Log in to OSS bridge upon arrival, document name of analyst on bridge
2. Capture pre photos and document any defects on site prior to arrival
3. Assemble and install trapeze
Trapeze support is required within 18" of hardline termination and 3' span
max thereafter.
4. Replace blank panels on AUX2 cabinet with power entry panels.
Port panel with 1 nine port entry and 3 single will face the RRU pole. The
port entry panel with 4 nine port blocks will face the hardline/GSM route.
5. Install RX-AIT units in 19" rack if not pre-installed.
6. Install power lugs on RMC units and terminate to -48vdc buss on
designated location. Breakers are pre-labeled, lugs to be provided in
install kit.
7. Install RX-AIT internal RF cabling on front of RX-AIT equipment as per
RX-AIT drawing.
8. Install alarm cable and run to 66 block in AUX2 cabinet.
9. Color code jumpers per RX-AIT drawing. Color code provided in RX-AIT
drawing.
10. Install jumpers from GSM to RX-AIT in Aux2 cabinet.
11. Install jumpers from RX-AIT to UMTS RRU rack. Length of jumpers will be
measured from center ring of RRU pole. Refer to RRU cad drawing.
12.Install jumpers from RX-AIT to hardlines. Refer to RX-AIT drawing.
13. Call OSS bridge and request sector block. When the sector is confirmed
to be down, unhook jumper from GSM and perform pre-sweep.
14. Unhook GSM jumper from top of base station and install new jumper path.
15. Perform system sweep on newly installed jumpers. -15.5 return loss
across usable band is passing.
Failing sweeps on hardline will require putting a precision load at the end
of the jumper at the hardline and saving sweep. Civil vendor will perform
repair.
16. Request OSS to perform a TRX test on sector to determine if all
amplifiers are functioning normally.
GSM sites with no TMA and no RX-AIT will read app. -112 for main and -112
for diversity.
GSM sites with TMA and no RX-AIT will read app. -106 for main and -106 for
diversity.
GSM sites with TMA and RX-AIT will read app. -100 for main and -100 for
diversity.
These values are accurate for determining RX sensitivity within 3dbm.
17. Repeat step 9-12 for remaining sectors.
18. Weatherproof lines at hardline.
19. Install cable entry boots or Rox Blox as per market standard.
All RF cables entering outdoor cabinet will be installed with drip loop.
All RF cables must be labeled with color code tape as they enter the
outdoor cabinets.
20. Install RJ45 connectors on pre-ran 25 pair cable. Follow standard 25
pair color code.
21 Install loopback on RJ45 connectors in AUX2 cabinet.
22.Once path to NIU is established, contact transport personnel and test
signal to the newly installed loop.
23. Capture photos of work and any defects, issues, or red flags.
24. Log out of site with OSS and record name of analyst.

 

ZTE experienced Optimization experts required

ZTE experienced Optimization experts required in India.

 Pls share cv's/ references at: niti.jain@axirconsulting.com

 

Nokia RF Engineer for EMEA

 

 

Vacancy: Nokia RF Engineer for EMEA

Start: ASAP

We are looking for an experienced Nokia RF Engineer who has worked on a swap out project/ has previous swap out experience.

If you are interested please send your CV to linkedin@firstpointgroup.com